Abstract
In press
Background. Urinalysis consists of clinical (physical, chemical and morphological) and microbiological studies. The results of urinalysis are significantly influenced by the quality of the sample and adequate preparation of the patient.
Aim. To consider important aspects of the preanalytical phase of urinalysis and the issue of patient preparation for sample collection to improve urinalysis results.
Materials and Methods. The study was conducted using the bibliosemantic method and systemic analysis as a private initiative of the authors, did not receive funding from grant programs, and the research topic was not officially registered in the state register of scientific topics. The European guideline on urinalysis, the European Association of Urology guideline, and other articles and guidelines in English from Medline published between 1990 and 2026 were used.
Research Ethics. The study materials were summarized without the participation of patients and without using their medical history, therefore, did not require the consent of ethical committees. Authors of selected studies adhered to ethical standards.
Results. Depending on the need, morning urine samples from the first or second urination or a random sample are used for clinical and microbiological studies, and a urine sample collected over a certain time is used for clinical studies only. In adults, urine for analysis is usually obtained by free urination and, if urine is supposed to come from the bladder, a sample from a midstream is used. The storage time of the sample at room temperature should not exceed 2–6 hours after urination, according to American experts, 30 minutes after urination in the case of microbiological investigation. Otherwise, it is necessary to preserve the sample by cooling in a refrigerator or using preservatives, for example, boric acid solutions. In microbiological investigation, contamination is indicated by the isolation of three or more types of bacteria or contaminating microorganisms. It is usually sufficient to obtain one urine sample from one patient for urinalysis.
Conclusions. Compliance with the components of the pre-analytical phase of urine testing and adequate preparation of the patient for sample collection will allow achieving the formulated goal, namely, improving the quality of urine analysis results.
Keywords: medical diagnostic and treatment technologies, microbiology, preanalytical phase, sample collection.
References
Leber AL, ed. Clinical Microbiology Procedures Handbook. 4th ed. Vols. 1, 2. Washington DC: ASM Press; 2016. 2,954 p.
Holm A, Aabenhus R. Urine sampling techniques in symptomatic primary-care patients: a diagnostic accuracy review. BMC Fam Pract. 2016;17:72. DOI: 10.1186/s12875-016-0465-4. PMID: 27278078.
LaRocco MT, Franek J, Leibach EK, Weissfeld AS, Kraft CS, Sautter RL, et al. Effectiveness of preanalytic practices on contamination and diagnostic accuracy of urine cultures: a laboratory medicine best practices systematic review and meta-analysis. Clin Microbiol Rev. 2016;29(1):105-47. DOI: 10.1128/CMR.00030-15. PMID: 26598386.
Hitzeman N, Greer D, Carpio E. Office-based urinalysis: a comprehensive review. Am Fam Physician. 2022;106(1):27-35B. PMID: 35839369.
Kouri TT, Hofmann W, Falbo R, Oyaert M, Schubert S, Gertsen JB, et al. The EFLM European Urinalysis Guideline 2023. Clin Chem Lab Med. 2024;62(9):1653-786. DOI: 10.1515/cclm-2024-0070. PMID: 38534005.
Kranz J, Bartoletti R, Bruyère F, Cai T, Geerlings S, Köves B, et al. European Association of Urology Guidelines on Urological Infections: Summary of the 2024 Guidelines. Eur Urol. 2024;86(1):27-41. DOI: 10.1016/j.eururo.2024.03.035. PMID: 38714379.
Miller JM, Binnicker MJ, Campbell S, Carroll KC, Chapin KC, Gonzalez MD, et al. Guide to utilization of the microbiology laboratory for diagnosis of infectious diseases: 2024 update by the Infectious Diseases Society of America (IDSA) and the American Society for Microbiology (ASM). Clin Infect Dis. 2024:ciae104. DOI: 10.1093/cid/ciae104. PMID: 38442248.
Manoni F, Gessoni G, Alessio MG, Caleffi A, Saccani G, Silvestri MG, et al. Mid-stream vs. first-voided urine collection by using automated analyzers for particle examination in healthy subjects: an Italian multicenter study. Clin Chem Lab Med. 2011;50(4):679-84. DOI: 10.1515/cclm.2011.823. PMID: 22505530.
Van der Wiel HE, Lips P, Nauta J, Netelenbos JC, Hazenberg GJ. Biochemical parameters of bone turnover during 10 days of bed rest and subsequent mobilization. Bone Miner. 1991;13(2):123-9. DOI: 10.1016/0169-6009(91)90079-f. PMID: 2059676.
Hooton TM, Roberts PL, Cox ME, Stapleton AE. Voided midstream urine culture and acute cystitis in premenopausal women. N Engl J Med. 2013;369(20):1883-91. DOI: 10.1056/NEJMoa1302186. PMID: 24224622.
Llor C, Moragas A, Aguilar-Sánchez M, García-Sangenís A, Monfà R, Morros R. Best methods for urine sample collection for diagnostic accuracy in women with urinary tract infection symptoms: a systematic review. Fam Pract. 2023;40(1):176-82. DOI: 10.1093/fampra/cmac058. PMID: 35652481.
Hoelmkjaer P, Bjerrum L, Mäkelä M, Siersma V, Holm A. Sampling of urine for diagnosing urinary tract infection in general practice - First-void or mid-stream urine? Scand J Prim Health Care. 2019;37(1):113-9. DOI: 10.1080/02813432.2019.1568708. PMID: 30689471.
Braisted J, Henderson T, Newman JW, Moore SC, Sampson J, McClain K, et al. Effects of preanalytical sample collection and handling on comprehensive metabolite measurements in human urine biospecimens. Am J Epidemiol. 2026;195(5):1201-9. DOI: 10.1093/aje/kwae347. PMID: 39284767.

This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.